Carrying and Keeping Explosives in Mines: Boxes, Handling Rules and Reserve Stations

Carrying and Keeping Explosives in Mines: Boxes, Handling Rules and Reserve Stations

An explosive is at its most vulnerable between the magazine and the face. It is handled, carried, set down and sometimes lifted into a cage, all in a place where roof, machinery and people share a narrow space. That is why mines have strict rules for how explosives and detonators are carried and where they are kept underground.

In this post, we go through the boxes used for carrying, how much one person can carry, what the shotfirer must watch for, the extra care needed in cages, on stairs and in sinking shafts, and what a proper reserve station looks like. These topics come up often in DGMS exams and in everyday blasting practice.

Quick summary Explosives and detonators travel in separate, locked, strong boxes. No box holds more than 5 kg of explosive, and the key stays with the shotfirer. Underground, the boxes are kept at a designated reserve station, and are taken to the face only when the holes are ready.
Key Numbers at a Glance 5 kg Maximum explosivein one box 1 Box carried by oneperson at a time 3 m Detonator box keptaway from explosive box 18 m Radius kept cleanand stone dusted 90 m No cable or switchwithin this distance 20 mm Stone dust layeron the floor
Six numbers that cover most of the questions on this topic.

What Should the Boxes Be Like?

The box is the first line of protection. Its job is to keep explosives and detonators from being knocked, dropped or mixed up. The usual requirements are:

  • Strong enough to protect the explosive or detonators from knocks.
  • Separate boxes for explosives and for detonators.
  • Explosive box: made of wood or galvanised iron sheet.
  • Detonator box: made of wood or leather, with a separate polythene compartment for each detonator.
  • Hinges and lock: made of brass, or a self-locking type, or a lock that opens with the exploder key.
  • A strong strap for carrying.
  • A different colour for each shift. For example, red for the first shift, yellow for the second and white for the third.
  • A number on every box. As far as possible, each shotfirer is given the same numbered box every day.
Colour-coded Boxes by Shift First shift: Red Box number marked Second shift: Yellow Box number marked Third shift: White Box number marked Example colours as given in the textbook. Follow the scheme laid down at your mine.
A box of the wrong colour in the wrong shift is spotted immediately.

How Much Can One Person Carry?

No box may hold more than 5 kg of explosive, and no person may carry more than one box at a time. DGMS can, under certain conditions, permit more than 5 kg in a box or more than one box per person, but unless that permission exists, the 5 kg and one-box limits apply.

Handling Rules for the Shotfirer

What goes in the box

  • Only one type of explosive in a box, up to 5 kg, and nothing else with it.
  • Detonators go in a separate box. The two wires of each detonator are kept short-circuited (twisted together).
  • Two types of detonator must not be kept in the same box.

Locks and keys

  • Boxes are locked at all times, and the key is always with the shotfirer.
  • A box is opened only when explosive or detonators have to be taken out, and it is closed again at once.
  • Detonators are taken out only when they are needed straight away.

Where the boxes go

  • Boxes stay at the reserve station. They are taken to the face only when the holes are ready.
  • The place where boxes are kept must have a sound roof and sides, with no electric cable or apparatus nearby.
  • Boxes are not dragged along the floor. They are lifted gently and set down.
  • The detonator box is kept away from the explosive box.

Personal discipline

  • Never put explosive or detonators in a pocket, even for a moment.
  • Carry the cap lamp battery on a belt at the waist, not on the shoulder. Make sure the headpiece or battery cannot fall onto explosive or detonators.
  • Only persons authorised by the manager may carry explosives. They must not be intoxicated, and must carry no bidi or cigarette and must not smoke.
Why a separate box for detonators? Detonators are more sensitive than explosive cartridges. Keeping them apart, with their wires short-circuited, makes an accidental firing far less likely and limits the damage if something does go wrong.

Carrying in a Cage, on Stairs and in a Sinking Shaft

Moving explosives between levels needs extra care, because a knock or a fall can happen very easily in a confined space.

  • In a dolly (cage): only the shotfirer or explosive carrier travels with the boxes. No other person rides with them.
  • On stairs: the box is tied to the body while going up or down.
  • In a sinking shaft: priming cartridges are prepared on the surface. Only the shotfirer takes them down, in a thick felt bag or a strong box so that they are protected from knocks.

The Reserve Station

What is a reserve station?

A reserve station is the place designated by the manager for keeping explosives underground. In every district, it is located a little way back from the face. It is the only place where explosive and detonator boxes are kept in the mine.

How much explosive can be kept there?

Only as much as is needed for that shift. The detonator box is kept 3 m away from the explosive box, and the boxes must be locked.

Before placing the boxes

Check the roof and sides first. There must be no loose coal or stone.

What should a reserve station be like?

Reserve Station (Schematic) 90 m: no electric cable or switch inside this distance 18 m radius: cleaned and stone dusted (20 mm layer on floor) Fenced area with "Reserve Station" board Explosive box Detonator box 3 m RESERVE STATION Dry place, sound roof and sides, no public thoroughfare, no risk of runaway tubs Not to scale. Based on textbook requirements.
Three nested zones: 90 m free of electrics, 18 m cleaned and stone dusted, 3 m between the two boxes.
  1. Location:
    • Not on a public thoroughfare, where people pass regularly.
    • No risk of a haulage tub running away and hitting it.
    • No electric cable or switch within 90 m.
    • A dry place.
  2. Roof and sides: Strong, with nothing loose or hanging. The roof must be properly supported.
  3. Cleanliness and stone dusting: Clean and stone dust the reserve station and the area within an 18 m radius, with a 20 mm thick layer of stone dust on the floor.
  4. Fencing and signboard: Fence the area and put up a board reading "Reserve Station".

Quick Revision and FAQ

Points to remember for exams
  • Maximum 5 kg of explosive per box. One box per person at a time (unless DGMS permits otherwise).
  • Explosive box: wood or galvanised iron. Detonator box: wood or leather, with a polythene compartment for each detonator.
  • Brass hinge and lock, or self-lock, or exploder-key lock. Key always with the shotfirer.
  • Box colours by shift: red, yellow, white. Each box is numbered.
  • Detonator wires are short-circuited. Never mix two types of detonator in one box.
  • Reserve station: designated by the manager. Detonator box 3 m from explosive box.
  • No cable or switch within 90 m. Clean and stone dust within 18 m, 20 mm layer on floor. Fencing and board.

Why are boxes carried at a belt rather than in a pocket?

Explosive and detonators must never be in a pocket, even briefly. A pocket gives no protection from knocks or friction. The strap and the strong box are there for a reason.

Why must the cap lamp battery be worn at the waist?

A battery or headpiece that falls from the shoulder can hit an explosive or detonator box. Waist-belt carrying keeps it away.

Why is the reserve station stone dusted?

Stone dust helps stop a coal dust explosion from spreading, and a clean, dusted area reduces fire and dust hazards around the stored explosive.

Who can carry explosives underground?

Only a person authorised by the manager, who is sober and carries no smoking material.

Conclusion

The rules for carrying and keeping explosives may look long, but they share a single idea: keep the quantity small, keep the boxes locked and separate, and keep the surroundings safe. A shotfirer who follows these habits every shift greatly lowers the chance of an accident, and a mine that builds its reserve stations properly gives that shotfirer the right place to work from.

Found this useful? Share it with a friend preparing for DGMS exams, and leave your questions in the comments.

Disclaimer: This post is for educational purposes and is based on standard mining textbook content. Limits, distances and procedures are laid down by law and by your mine's approved rules. Always follow the Coal Mines Regulations, the Explosives Rules, the latest DGMS circulars and your mine's own approved procedures.

Post a Comment

0 Comments