Blasting & Explosives MCQ Questions - Part 02
💥 Blasting & Explosives MCQ Questions - Part 02
16. Safety fuse burns at an approximate rate of:
A. 30 sec/m B. 60 sec/m C. 90 sec/m D. 120 sec/m
Show Answer Answer: B. 60 sec/m
17. Delay detonators are used to:
A. Prevent misfire B. Achieve sequential blasting C. Increase VOD D. Reduce stemming length
Show Answer Answer: B. Achieve sequential blasting
18. Cordtex is a type of:
A. Electric detonator B. Non-electric detonator C. Detonating fuse D. Blasting machine
Show Answer Answer: C. Detonating fuse
19. Foreman's signal before blasting is usually:
A. One whistle B. Two whistles C. Siren or whistle signals as per bye-laws D. No signal required
Show Answer Answer: C. Siren or whistle signals as per bye-laws
20. Connecting detonator wires should always be:
A. Twisted tightly with bare hands B. Properly insulated and shunted C. Connected after charging D. Connected before charging
Show Answer Answer: B. Properly insulated and shunted
21. In underground fiery seams, maximum number of shots allowed at a face at one time is:
22. Multi-shot blasting in fiery seams must use:
A. Normal fuse B. Approved delay detonators with permitted explosives C. Detonating cord only D. None
Show Answer Answer: B. Approved delay detonators with permitted explosives
23. The most common cause of misfires is:
A. Defective explosive B. Disconnection of detonator wires C. Bad stemming D. Wrong charge weight
Show Answer Answer: B. Disconnection of detonator wires
24. Misfires should be dealt with only after at least:
A. 5 minutes B. 15 minutes C. 30 minutes D. 1 hour
Show Answer Answer: C. 30 minutes
25. Which of the following is NOT a permitted stemming material?
A. Inert sand/dust B. Clay balls C. Coal dust D. Drill cuttings
Show Answer Answer: C. Coal dust
26. Blasting operations must be supervised by:
A. Mine Manager B. Qualified Shotfirer C. Surveyor D. Any worker
Show Answer Answer: B. Qualified Shotfirer
27. In fiery seams, which type of explosives are strictly banned?
A. Permitted B. Non-permitted ordinary explosives C. Water-gel D. ANFO (unapproved)
Show Answer Answer: B. Non-permitted ordinary explosives
28. Which instrument is used to test electric detonators before use?
A. Ohmmeter/blasting ohmmeter B. Ammeter C. Multimeter D. Megger
Show Answer Answer: A. Ohmmeter/blasting ohmmeter
29. Charging of boreholes with explosives must be done with:
A. Wooden tamping rods B. Iron rods C. Steel sticks D. Bare hands
Show Answer Answer: A. Wooden tamping rods
30. Which DGMS rule prohibits relighting of short fuse shots?
A. CMR 128 B. CMR 153 C. CMR 160 D. CMR 174
Show Answer Answer: C. CMR 160
0 Comments