Methane Control | Indian Minerology
Part 4: Methane Control
Key Learning Objective: Master methane management techniques as per CMR 2017 Chapter VII (Reg 112-132), DGMS Methane Policy 2020, and practical opencast/underground control measures.
4.1 Methane Monitoring Procedures
🚨 STATUTORY METHANE LIMITS 🚨
Return Airway: <1 continuous="" face:="" goaf:="" monitoring="" small=""> 1>
Return Airway: <1 continuous="" face:="" goaf:="" monitoring="" small=""> 1>
| Location | Max CH₄ Limit | Action Required | CMR Reference |
|---|---|---|---|
| Return Airway | 1.0% | Increase ventilation | CMR 117(1) |
| Working Face | 1.25% | Stop mechanical extraction | CMR 117(2) |
| Goaf Edge | 0.5% | Seal barriers, withdraw men | CMR 132 |
| Intake Airway | 0.5% | Investigate source | CMR 116 |
4.2 Ventilation Strategies for Methane Control
💨 Auxiliary Ventilation
- Forcing/ Exhausting type
- Min 3m/s velocity
- Flexible ducting
- 30,000 CMH capacity
🌪️ Main Fan Management
- Water-gauge monitoring
- Auto-reverse facility
- 75,000-5,00,000 CMH
- Daily quantity survey
🛠️ Stone Dusting
- 15% incombustible content
- Roadways: 2.5kg/m²
- Goaf: 40% coverage
- Monthly sampling
4.3 Methane Drainage Systems
Mandatory for gassy seams (>9m³/tonne gas content)
Drainage Methods:
- In-seam boreholes: 50-100m horizontal
- Goaf edge drainage: Vertical wells
- Pre-drainage: Before extraction
- Ventilation through pipes: To surface
- Cross-measure drilling: 30° angle
Success Criteria: CH₄ reduced to <0 .5="" at="" face="" p=""> 0>
4.4 Emergency Response for Methane Alarms
🚨 METHANE ALARM PROTOCOL 🚨
1% CH₄ = YELLOW ZONE → 1.25% = RED ZONE
- All electrical equipment OFF
- Stop conveyor/haulage
- Increase ventilation (aux fans)
- Withdraw to fresh air base
- Continuous monitoring every 15 min
- Manager approval for re-entry
4.5 Preventive Measures
- Pre-shift gas checks (mandatory)
- Two-fan ventilation systems
- Methane forecasting from degasification data
- Gas emission rate surveys
- Seal integrity testing (weekly)
- Power cut-off at 1.5% CH₄ (auto)
⚠️ Exam Must-Know Facts:
- CMR 117(3): >1.5% CH₄ = All men withdrawn
- Aux fan capacity: 0.3m³/s per 100m duct
- Stone dust sampling: Form V-26
- Methane ignition temp: 540-630°C
- Goaf drainage: 50% emission control