Ventilation Principles | Indian Minerology
Part 6: Ventilation Principles
Key Learning Objective: Master ventilation planning, quantity surveys, fan performance, and statutory air velocity requirements (CMR 2017 Chapter VI Reg 104-111).
6.1 Natural vs Mechanical Ventilation
🌤️ Natural Ventilation
- Temperature/pressure difference
- Shallow mines only (<100m)
- No control over direction
- Supplementary only
- Monsoon dependent
⚙️ Mechanical Ventilation
- Main fans (75k-5L CMH)
- Auxiliary fans (30k CMH)
- Booster fans (deep mines)
- Directional control
- 24×7 operation
6.2 Statutory Airflow Requirements
| Roadway Type | Min Velocity (m/s) | Quantity (m³/s per 100m) | CMR Reference |
|---|---|---|---|
| Intake Airway | 0.5 | 3.0 | CMR 106 |
| Return Airway | 1.0 | 6.0 | CMR 107 |
| Face Roadway | 1.5 | 9.0 | CMR 108 |
| Aux Vent Duct | 3.0 | 30,000 CMH | DGMS Circular |
6.3 Airflow Measurement Techniques
🎯 Quantity Survey Methods
| Method | Instrument | Accuracy | Application |
|---|---|---|---|
| Traversing | Anemometer + planimeter | ±5% | Main airways |
| Tube Bundle | Manometer array | ±3% | Aux ventilation |
| Vane Anemometer | Digital vane type | ±2 m/s | Spot readings |
| Smoke Test | Smoke tube | Qualitative | Direction check |
6.4 Fan Laws and Performance
📈 Fan Performance Formulas
Main Fan Capacity:
[ Q = A \times V ]
Q=Quantity (m³/s), A=Area(m²), V=Velocity(m/s)
[ Q = A \times V ]
Q=Quantity (m³/s), A=Area(m²), V=Velocity(m/s)
Aux Fan Pressure:
[ P = \frac{L \times f \times V^2}{2g} ]
P=Pressure(Pa), L=Duct length(m), f=friction factor
[ P = \frac{L \times f \times V^2}{2g} ]
P=Pressure(Pa), L=Duct length(m), f=friction factor
Fan Law #1:
[ Q propto N ]
Quantity proportional to RPM
[ Q propto N ]
Quantity proportional to RPM
Fan Law #2:
[ P propto N^2 ]
Pressure proportional to RPM²
[ P propto N^2 ]
Pressure proportional to RPM²
6.5 Ventilation Planning & Leakage Control
🗺️ Ventilation Survey Components:
- Air door conditions
- Stoppings integrity
- Regulators position
- Fan water-gauge
- Duct leakage check
- Leakage <20% total quantity
📋 Daily Ventilation Report (Form V-20):
- Main fan on/off time
- Aux fan pressure
- Face velocity readings
- Total quantity survey
- Gas concentrations
- Leakage percentage
⚠️ Exam Formulae & Limits:
- Leakage limit: 25% max
- Aux duct velocity: 10-15 m/s
- Fan efficiency: 65-75%
- Water-gauge units: 1mmWG=9.81Pa
- Form V-20: Daily ventilation return
- Air door gap: <75mm